1. Feature
Oscilloscope Function
Logic Analyzer Function
Arb. Waveform Generator Function
2. Specifications
Model | MSO5054FG |
Acquisition | |
Sample Rate | Real-Time Sample: 1GS/s |
Acquisition Modes | |
Normal | Normal data only |
Peak Detect | High-frequency and randon glith capture |
Average | Wavefom Average, selectable 4,8,16,32,64,128 |
Inputs | |
Inputs Coupling | AC, DC, GND |
Inputs Impendance | 1MΩ±2% ‖20pF±3pF |
Probe Attenuation | 1X, 10X |
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X |
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above |
Horizontal System | |
Sample Rate Range | 1GS/s |
Waveform Interpolation | (sin x)/x |
Record Length | 1M |
SEC/DIV Range | 4ns/div to 40s/div, in a 2, 4, 8 sequence, |
Sample Rate and Delay Time Accuracy |
±50ppm(at over any ≥1ms time interval) |
Position Range |
20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s; |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
Vertical System | |
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously |
Position Range |
2mV/div to 5V/div |
Bandwidth | 40MHz; |
Rise Time at BNC( typical) | 8.8ns; |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V 5V/div, ±50V |
Math | +, -, *, /, FFT |
FFT | Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point |
Bandwidth Limit | 20MHz |
Low Frequency Response (-3db) | ≤10Hz at BNC |
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
DC Measurement Accuracy, Average Acquisition Mode |
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for s |
Volts Measurement Repeatability, Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Trigger System | |
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes | Auto, Normal, Single |
Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Sensitivity (Edge Trigger Type) |
DC(CH1,CH2, CH3, CH4): 1div from DC to 10MHz;1.5div from 10MHz to Full; DC(EXT): 200mV from DC to Full; DC(EXT/5):1V from DC to Full; AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz |
Trigger Level Range |
CH1, CH2, CH3, CH4: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V |
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1, CH2, CH3, CH4: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); |
Set Level to 50%(typical) | Operates with input signals ≥50Hz |
Video Trigger | |
Video Trigger Type |
CH1, CH2, CH3, CH4: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V |
Signal Formats and Field Rates, Video Trigger Type | Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
Holdoff Range | 100ns ~ 10s |
Pulse Width Trigger | |
Pulse Width Trigger Mode | Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse |
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width |
Pulse Width Range | 20ns ~ 10s |
Slope Trigger | |
Slope Trigger Mode | Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope |
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
Time Range | 20ns ~ 10s |
Overtime Trigger | |
Over Time Mode | Rising edge or Falling edge |
Time Range | 20ns ~ 10s |
Alternative Trigger | |
Trigger on CH1 | Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger on CH2 | Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger Frequency Counter | |
Readout Resolution | 6 digits |
Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) |
Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth |
Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work. |
Measurement | |
Cursor Measurement |
Manual: Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT); Tracing: The valtage and time at a waveform point; |
Auto Measuerment | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF |
Display | |
Display Type | 7 inch 64K color TFT (diagonal liquid crystal) |
Display Resolution | 800 horizontal by 480 vertical pixels |
Display Contrast | Adjustable (16 gears) with the progress bar |
Logic Analyzer Specifications | |
Channels | 8 Channels |
Max. Input Impendence | 200K(C=10p) |
Input Voltage Range | 0V~3V |
Logic Threshold Range | 0V~3V |
Max. Sample Rate | 500MHz |
Compatible Input | TTL, CMOS, ECL |
Sample Depth | 1M |
Trigger | |
Edge Trigger | D0-D7 select slope (rising or falling edge) |
Pulse Width | D0-D7 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width |
Code-type | D0-D7 select code-type (H, L, X) |
Duration | D0-D7 select persist time and trigger when (data terminate, data start, and data delay) |
Queue | D0-D7 select specific data index (0-3) and code-type (H, L, X) |
Repeat | D0-D7 select code-type (H, L, X) and repeat times |
Arb. Waveform Generator Specifications (MSO5054FG) | |
Wave frequency | DC~25MHz |
DAC clock | 2K~200MHz adjustable |
Waveform Length | 4KSa |
Vertical Resolution | 12 bit |
Frequency stabilization | <30ppm |
Amplitude | ±3.5V Max. |
Output impedance | 50 Ω |
Output current | 50mA Ipeak=50mA |
System Bandwidth | 25M |
Wave distortion | -50dBc(1KHz), -40dBc(10KHz) |
Frequency area | DC~50MHz |
Input Amplitude | 400mVpp~18Vpp |
Coupling | DC |
Frequency precision | ±Time Base Error ±1 Count |
input impedance | > 100KΩ |
Pattern Generator | 12Bit |
Probe Compensator Output | |
Output Voltage( typical) | About 5Vpp into ≥1MΩ load |
Frequency(typical) | 1kHz |
Power Supply | |
Supply Voltage |
100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ |
Power Consumption | <30W |
Fuse | 2A, T rating, 250V |
Environmental | |
Temperature |
Operating: 32℉ to 122℉ (0℃ to 50℃); Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃) |
Cooling Method | Convection |
Humidity |
+104℉ or below (+40℃ or below): ≤90% relative humidity; 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity |
Altitude |
Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet) |
Mechanical | |
Size | Length 385mm; Width 200mm; Height 245mm |
Weight | 3.5KG(with Packing); 2.08KG(without Packing) |
3. Standard Accessory:
4. Function Pictures: